ICS TRIPLEX 9803機(jī)器人備件,備件庫存
如果當(dāng)前編程的密碼未知,請(qǐng)使用此號(hào)碼咨詢工廠服務(wù)部門。使用解密程序,可以確定密碼。n PASSCODE n[ENTER](輸入密碼)獲取更多信息,請(qǐng)輸入密碼:范圍:1到8個(gè)數(shù)字。僅當(dāng)密碼不為“0”且設(shè)定點(diǎn)訪問為“受限”時(shí)才可見。設(shè)定值訪問:允許范圍:允許,限制。僅當(dāng)密碼為“0”或設(shè)定點(diǎn)訪問為“允許”時(shí)才可見。更改密碼:否范圍:否,是。僅當(dāng)密碼為“0”或設(shè)定點(diǎn)訪問為“允許”時(shí)才可見。輸入退出消息退出消息退出輸入退出消息幫助GE Multilin 469電機(jī)管理繼電器4-7 4設(shè)定值4.2 S1 469設(shè)置4 4.2.2首選路徑:設(shè)定值S1 469設(shè)定值×首選某些特性可以針對(duì)不同情況進(jìn)行修改。通常,此子組不需要更改。?默認(rèn)消息循環(huán)時(shí)間:如果選擇了多個(gè)默認(rèn)消息,則顯示會(huì)自動(dòng)循環(huán)顯示這些消息??梢愿娘@示時(shí)間以適應(yīng)不同的用戶偏好。?默認(rèn)消息超時(shí):如果在一段時(shí)間內(nèi)沒有按下任何鍵,則繼電器將自動(dòng)掃描一組編程的默認(rèn)消息。可以修改此時(shí)間,以確保在編程或讀取實(shí)際值期間消息在屏幕上保留足夠長的時(shí)間。默認(rèn)掃描開始后,按任意鍵將返回屏幕上查看的最后一條消息。?平均電機(jī)負(fù)載計(jì)算周期:該設(shè)置點(diǎn)調(diào)整計(jì)算平均電機(jī)負(fù)載的時(shí)間周期。該計(jì)算是一個(gè)滑動(dòng)窗口,在電機(jī)啟動(dòng)期間被忽略。?溫度顯示:溫度測量值可以以攝氏度或華氏度顯示。每個(gè)溫度值顯示為°C或°F。RTD設(shè)定值始終以攝氏度顯示。?跟蹤存儲(chǔ)器觸發(fā)器位置:設(shè)置波形捕獲的觸發(fā)器位置。該值表示觸發(fā)(跳閘)之前捕獲并記錄在跟蹤內(nèi)存緩沖區(qū)中的周期百分比。?TRACE MEMORY BUFFERS(跟蹤存儲(chǔ)器緩沖區(qū)):設(shè)置要捕獲的跟蹤數(shù)和捕獲的10個(gè)波形中每個(gè)波形的周期數(shù)。注:每條記錄道捕獲10個(gè)波形,顯示所有電流和電壓。
Consult the factory service department with this number if the currently programmed passcode is unknown. Using a deciphering program, the passcode can be determined. n PASSCODE n [ENTER] for more ENTER PASSCODE FOR ACCESS: Range: 1 to 8 numeric digits. Seen only if passcode is not “0” and SETPOINT ACCESS is “Restricted”. SETPOINT ACCESS: Permitted Range: Permitted, Restricted. Seen only if the passcode is “0” or SETPOINT ACCESS is “Permitted”. CHANGE PASSWORD: No Range: No, Yes. Seen only if the passcode is “0” or SETPOINT ACCESS is “Permitted”. ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE ENTER MESSAGE ESCAPE MESSAGE HELP GE Multilin 469 Motor Management Relay 4-7 4 SETPOINTS 4.2 S1 469 SETUP 4 4.2.2 PREFERENCES PATH: SETPOINTS ? S1 469 SETUP ?× PREFERENCES Some characteristics can be modified for different situations. Normally this subgroup will not require changes. ? DEFAULT MESSAGE CYCLE TIME: If multiple default messages are chosen, the display automatically cycles through those messages. The display time can be changed to accommodate different user preferences. ? DEFAULT MESSAGE TIMEOUT: If no keys are pressed for a period of time then the relay will automatically scan a programmed set of default messages. This time can be modified to ensure messages remain on the screen long enough during programming or reading actual values. Once default scanning starts, pressing any key will return the last message viewed to the screen. ? AVERAGE MOTOR LOAD CALCULATION PERIOD: This setpoint adjusts the period of time over which the average motor load is calculated. The calculation is a sliding window and is ignored during motor starting. ? TEMPERATURE DISPLAY: Temperature measurements may be displayed in either Celsius or Fahrenheit. Each temperature value is displayed as °C or °F. RTD setpoints are always displayed in degrees Celsius. ? TRACE MEMORY TRIGGER POSITION: Sets the trigger position for waveform capture. This value represents the percentage of cycles captured and recorded in the trace memory buffer prior to the trigger (trip). ? TRACE MEMORY BUFFERS: Sets the number of traces to capture and the number of cycles for each of the 10 waveforms captured. Note: 10 waveforms are captured for each trace, showing all currents and voltages.