ICS TRIPLEX T3441A備件庫(kù)存,自動(dòng)化模塊備件
i在惡劣的照明條件下,為提高能見度而采用背光照明。消息以純英語顯示,不需要使用說明手冊(cè)進(jìn)行解讀。當(dāng)鍵盤和顯示屏未使用時(shí),顯示屏默認(rèn)為用戶定義的狀態(tài)信息。任何跳閘、報(bào)警或啟動(dòng)塊都會(huì)立即顯示,自動(dòng)覆蓋默認(rèn)信息。3.1.2 LED指示器有三組LED指示器。它們是469狀態(tài)、電機(jī)狀態(tài)和輸出繼電器。圖3–1:469 LED指示燈a)469狀態(tài)LED指示燈?469運(yùn)行中:該LED指示控制電源接通,所有監(jiān)控輸入/輸出和內(nèi)部系統(tǒng)正常,469已編程,469處于保護(hù)模式,而不是模擬模式。當(dāng)469處于模擬或測(cè)試模式時(shí),該LED閃爍。?設(shè)置點(diǎn)訪問:此LED指示已安裝訪問跳線,且密碼保護(hù)已得到滿足;可更改和存儲(chǔ)設(shè)定值計(jì)算機(jī)RS232:當(dāng)通信端口上有任何活動(dòng)時(shí),該指示燈閃爍。如果輸入數(shù)據(jù)有效,則指示燈持續(xù)亮起。?計(jì)算機(jī)RS485:當(dāng)通信端口上有任何活動(dòng)時(shí)閃爍。如果輸入數(shù)據(jù)有效且用于繼電器中編程的從屬地址,則保持穩(wěn)定。?輔助RS485:當(dāng)通信端口上有任何活動(dòng)時(shí)閃爍。如果輸入數(shù)據(jù)有效且用于繼電器中編程的從屬地址,則保持穩(wěn)定。?LOCKOUT(鎖定):表示啟動(dòng)嘗試將被編程的鎖定時(shí)間或仍然存在的條件阻止。?重置可能性:可重置跳閘或鎖定報(bào)警。按鍵清除跳閘或報(bào)警。?消息:當(dāng)發(fā)生跳閘、報(bào)警或啟動(dòng)阻塞時(shí)閃爍。按鍵滾動(dòng)瀏覽診斷信息。當(dāng)查看設(shè)定值和實(shí)際值消息時(shí),該LED保持穩(wěn)定。按下該鍵將顯示為默認(rèn)消息。b) 電機(jī)狀態(tài)LED指示器?停止:電機(jī)根據(jù)零相電流和啟動(dòng)器狀態(tài)輔助觸點(diǎn)反饋停止。?啟動(dòng):電機(jī)正在啟動(dòng)。?運(yùn)行:電機(jī)在過載拾取水平以下正常運(yùn)行。?過載:電機(jī)在過載傳感器上方運(yùn)行。?不平衡拾?。弘娏鞑黄胶馑揭殉^不平衡報(bào)警或跳閘水平。?接地傳感器:接地電流水平已超過接地故障報(bào)警或跳閘水平。?熱RTD:其中一個(gè)RTD測(cè)量值已超過其RTD報(bào)警或跳閘水平。808706A2.CDR RESET NEXT NEXT 3-2 469電機(jī)管理繼電器GE Multilin 3.1 FACEPLATE INTERFACE 3用戶界面3?負(fù)載損失:平均電機(jī)電流已降至欠電流報(bào)警或跳閘水平以下;或者功耗已降至低于功率不足警報(bào)或跳閘水平。c) 輸出繼電器LED指示器?R1跳閘:R1跳閘繼電器已運(yùn)行(通電)。?R2輔助:R2輔助繼電器已工作(通電)。?R3輔助:R3輔助繼電器已工作(通電)。?R4報(bào)警:R4報(bào)警繼電器已運(yùn)行(通電)。?R5塊啟動(dòng):R5塊啟動(dòng)繼電器已運(yùn)行(通電)。?R6維修:R6維修繼電器已運(yùn)行(斷電,R6故障保護(hù),正常通電)。3.1.3 RS232程序端口該端口用于連接便攜式PC。可在任何位置創(chuàng)建設(shè)定點(diǎn)文件,并通過該端口下載469PC軟件。也可以對(duì)設(shè)定值和實(shí)際值進(jìn)行本地詢問。新固件也可以通過該端口下載到469閃存
s backlit for visibility under poor lighting conditions. Messages are displayed in plain English and do not require an instruction manual to decipher. When the keypad and display are not being used, the display defaults to the user-defined status messages. Any trip, alarm, or start block is displayed immediately, automatically overriding the default messages. 3.1.2 LED INDICATORS There are three groups of LED indicators. They are 469 Status, Motor Status, and Output Relays. Figure 3–1: 469 LED INDICATORS a) 469 STATUS LED INDICATORS ? 469 IN SERVICE: This LED indicates that control power is applied, all monitored inputs/outputs and internal systems are OK, the 469 has been programmed, and the 469 is in protection mode, not simulation mode. This LED flashes when the 469 is in simulation or testing mode. ? SETPOINT ACCESS: This LED indicates that the access jumper is installed and passcode protection has been satisfied; setpoints may be altered and stored. ? COMPUTER RS232: This LED flashes when there is any activity on the communication port. The LED remains on solid if incoming data is valid. ? COMPUTER RS485: Flashes when there is any activity on the communication port. Remains on solid if incoming data is valid and intended for the slave address programmed in the relay. ? AUXILIARY RS485: Flashes when there is any activity on the communication port. Remains on solid if incoming data is valid and intended for the slave address programmed in the relay. ? LOCKOUT: Indicates start attempts will be blocked either by a programmed lockout time or a condition that is still present. ? RESET POSSIBLE: A trip or latched alarm may be reset. Press the key to clear the trip or alarm. ? MESSAGE: Flashes when a trip, alarm, or start block occurs. Pressing the key scrolls through diagnostic messages. This LED remains solid when setpoint and actual value messages are being viewed. Pressing the key returns the display to the default messages. b) MOTOR STATUS LED INDICATORS ? STOPPED: The motor is stopped based on zero phase current and starter status auxiliary contact feedback. ? STARTING: Motor is starting. ? RUNNING: Motor is running normally below overload pickup level. ? OVERLOAD: Motor is running above overload pickup. ? UNBALANCE PICKUP: Level of current unbalance has exceeded the unbalance alarm or trip level. ? GROUND PICKUP: Level of ground current has exceeded the ground fault alarm or trip level. ? HOT RTD: One of the RTD measurements has exceeded its RTD alarm or trip level. 808706A2.CDR RESET NEXT NEXT 3-2 469 Motor Management Relay GE Multilin 3.1 FACEPLATE INTERFACE 3 USER INTERFACES 3 ? LOSS OF LOAD: Average motor current has fallen below the undercurrent alarm or trip level; or power consumption has fallen below the underpower alarm or trip level. c) OUTPUT RELAY LED INDICATORS ? R1 TRIP: R1 Trip relay has operated (energized). ? R2 AUXILIARY: R2 Auxiliary relay has operated (energized). ? R3 AUXILIARY: R3 Auxiliary relay has operated (energized). ? R4 ALARM: R4 Alarm relay has operated (energized). ? R5 BLOCK START: R5 Block Start relay has operated (energized). ? R6 SERVICE: R6 Service relay has operated (de-energized, R6 is failsafe, normally energized). 3.1.3 RS232 PROGRAM PORT This port is intended for connection to a portable PC. Setpoint files may be created at any location and downloaded through this port with the 469PC software. Local interrogation of setpoints and actual values is also possible. New firmware may also be downloaded to the 469 flash memory through this port. Upgrading of the relay firmware