t隨時(shí)間執(zhí)行的啟動(dòng)器操作的數(shù)量。每當(dāng)電機(jī)停止時(shí),無(wú)論是跳閘還是正常停止,該計(jì)數(shù)器都會(huì)遞增。這可能是起動(dòng)機(jī)維護(hù)的有用信息。當(dāng)計(jì)數(shù)器達(dá)到50000時(shí),該計(jì)數(shù)器將重置為0。該信息可通過(guò)S1 469 SETUP\ INSTALLATION \ RESET STARTER information(S1 469設(shè)置\安裝\重置啟動(dòng)器信息)設(shè)置點(diǎn)清除。如果其中一個(gè)可分配的數(shù)字輸入被編程為數(shù)字計(jì)數(shù)器,則計(jì)數(shù)器測(cè)量值將顯示在此處。如果計(jì)數(shù)器為遞增類型,或使用S1 469 SETUP\CLEAR DATA\PRESET DIGITAL counter(設(shè)置清除數(shù)據(jù))設(shè)定值預(yù)設(shè)為預(yù)定值,則計(jì)數(shù)器可重置為零。5.5.3計(jì)時(shí)器469個(gè)計(jì)時(shí)器中的一個(gè)累積電機(jī)的總運(yùn)行時(shí)間。這可能有助于安排日常維護(hù)。當(dāng)此計(jì)時(shí)器達(dá)到100000時(shí),它將重置為0??墒褂肧1 469 SETUP\ INSTALLATION \ RESET MOTOR INFORMATION(S1 469設(shè)置\安裝\重置電機(jī)信息)設(shè)置點(diǎn)清除該計(jì)時(shí)器??梢栽诖颂幉榭础伴_始之間的時(shí)間計(jì)時(shí)器”值。該值可能有助于計(jì)劃電機(jī)停機(jī)。啟動(dòng)/小時(shí)定時(shí)器值也編程為定子熱測(cè)試軸承RTD:0°C EVENT01范圍:-50至250°C,----(無(wú)RTD)僅當(dāng)至少一個(gè)RTD編程為軸承熱測(cè)試其他RTD:0℃EVENT01時(shí)可見,范圍:-50到250°C;----(無(wú)RTD:僅當(dāng)至少有一個(gè)RTD被編程為其他環(huán)境RTD:0oC EVENT001范圍:-50~250°C時(shí)可見,----(無(wú)RTD)僅當(dāng)至少1個(gè)RTD編程為環(huán)境Vab:0 Vbc:0 Vca:0 A EVENT01范圍:0至20000 A僅當(dāng)VT連接編程為None Van時(shí)可見:0 Vbn:0 Vcn:0 A VENTT01范圍:1至20000 A只當(dāng)VT連接被編程為Y型系統(tǒng)頻率EVENT01:0.00 Hz范圍:0.00時(shí)可見,20.00至120.00 Hz 0 kW 0 kVA 0 kvar EVENT01范圍:–50000至50000 kVA僅當(dāng)VT連接編程為無(wú)功率因數(shù)EVENT01時(shí)可見:0.00范圍:0.01至0.99鉛實(shí)際值5每次事件發(fā)生時(shí),事件記錄器存儲(chǔ)電機(jī)和系統(tǒng)信息。事件描述與時(shí)間和日期標(biāo)記一起存儲(chǔ),用于故障排除。事件包括所有跳閘、可選的任何警報(bào)(服務(wù)警報(bào)和469未插入警報(bào)除外,這些警報(bào)始終記錄為事件)、控制電源損失、控制電源的應(yīng)用、緊急重啟以及阻塞功能激活時(shí)電機(jī)啟動(dòng)。如果模塊啟動(dòng)觸點(diǎn)短路以繞過(guò)469并啟動(dòng)電機(jī),則可能發(fā)生后一種事件。事件01是最近的事件,事件40是最早的事件。每一個(gè)新事件都會(huì)使另一個(gè)事件記錄上升一個(gè),直到到達(dá)事件40。當(dāng)新事件發(fā)生時(shí),事件40中的事件記錄丟失。此信息可以是MESSAGE ESCAPE MESSAGE ESCAPE GE Power Management 469電機(jī)管理繼電器5-25 5實(shí)際值5.6 A5事件記錄器5表5–4:事件原因跳閘警報(bào)(可選事件)其他不完整序列跳閘遠(yuǎn)程報(bào)警服務(wù)警報(bào)
he number of starter operations performed over time. This counter is incremented any time the motor is stopped, either by a trip or normal stop. This may be useful information for starter maintenance. When the counter reaches 50000, that counter will reset to 0. This information may be cleared with the S1 469 SETUP\INSTALLATION\RESET STARTER INFORMATION setpoint. If one of the assignable digital inputs is programmed as Digital Counter, that counter measurement will appear here. The counter can be reset to zero if the counter is of the incrementing type or pre-set to a predetermined value using the S1 469 SETUP\CLEAR DATA\PRESET DIGITAL COUNTER setpoint. 5.5.3 TIMERS One of the 469 timers accumulates the total running time for the Motor. This may be useful for scheduling routine maintenance. When this timer reaches 100000, it will reset to 0. This timer can be cleared using the S1 469 SETUP \ INSTALLATION \ RESET MOTOR INFORMATION setpoint. The TIME BETWEEN STARTS TIMER value may be viewed here. This value might be useful for planning a motor shutdown. The STARTS/HOUR TIMER value is also programmed as Stator HOTTEST BEARING RTD: 0°C EVENT01 Range: –50 to 250°C, ---- (no RTD) Seen only if at least 1 RTD is programmed as Bearing HOTTEST OTHER RTD: 0°C EVENT01 Range: –50 to 250°C, ---- (no RTD) Seen only if at least 1 RTD is programmed as Other AMBIENT RTD: 0°C EVENT01 Range: –50 to 250°C, ---- (no RTD) Seen only if at least 1 RTD is programmed as Ambient Vab: 0 Vbc: 0 Vca: 0 A EVENT01 Range: 0 to 20000 A Seen only if VT Connection programmed as None Van: 0 Vbn: 0 Vcn: 0 A EVENT01 Range: 0 to 20000 A Seen only if VT Connection programmed as Wye SYSTEM FREQUENCY EVENT01: 0.00 Hz Range: 0.00, 20.00 to 120.00 Hz 0 kW 0 kVA 0 kvar EVENT01 Range: –50000 to 50000 kVA Seen only if VT Connection programmed as None POWER FACTOR EVENT01: 0.00 Range: 0.01 to 0.99 Lead ACTUAL VALUES 5 The event recorder stores motor and system information each time an event occurs. An event description is stored along with a time and date stamp for troubleshooting purposes. Events include all trips, any alarm optionally (except Service Alarm, and 469 Not Inserted Alarm, which always records as events), loss of control power, application of control power, emergency restarts, and motor starts when a blocking function is active. The latter event could occur if the block start contacts were shorted out to bypass the 469 and start the motor. EVENT 01 is the most recent event and EVENT 40 is the oldest event. Each new event bumps the other event records up one until EVENT 40 is reached. The event record in EVENT 40 is lost when a new event occurs. This information can MESSAGE ESCAPE MESSAGE ESCAPE GE Power Management 469 Motor Management Relay 5-25 5 ACTUAL VALUES 5.6 A5 EVENT RECORDER 5 Table 5–4: CAUSE OF EVENTS TRIPS ALARMS (OPTIONAL EVENTS) OTHER Incomplete Seq Trip Remote Alarm Service Alarm