IS220PDIOH1B 336A5026ADP6燃機(jī)工控模塊
測(cè)量功能(UIfPQ) 應(yīng)用電壓、電流、實(shí)際功率和視在功率的測(cè)量頻率,例如用于在控制單元的監(jiān)視器上顯示或用于轉(zhuǎn)移到高級(jí)站控制系統(tǒng),以便進(jìn)一步處理。
B、 特征單相測(cè)量(1個(gè)電壓和1個(gè)電流I/P)相對(duì)地電壓測(cè)量或相對(duì)相電壓測(cè)量(如果安裝了三相Y連接的v.t)基頻分量的評(píng)估頻率范圍(0.9…1.1)內(nèi)的高精度f(wàn)N除非電壓過(guò)低,否則測(cè)量的電壓頻率
在這種情況下,測(cè)量電流;如果兩者都太低,則顯示為0.000 Hz每秒至少測(cè)量一次
對(duì)電壓和電流中的直流分量不敏感對(duì)電壓和電流諧波不敏感
電路和測(cè)量補(bǔ)償規(guī)定
相位誤差。測(cè)量變量輸入
測(cè)量變量輸入可連接到以下裝置:
資料來(lái)源:測(cè)量變量常數(shù),整數(shù)或百分比范圍。
保護(hù)功能測(cè)量變量,角度范圍為±180.00°,電流和電壓在相應(yīng)的單元中傳送。
來(lái)自IBB的輸入,整數(shù)范圍。模擬信道。3.6.4.1.6.測(cè)量變量輸出
測(cè)量變量輸出可連接到以下裝置:水槽:測(cè)量編號(hào)1…64。每次FUPLA時(shí),必須再次加載FUPLA代碼
配置已更改。進(jìn)行內(nèi)部FUPLA更改后并復(fù)制文件“project1.bin”和這是一個(gè)項(xiàng)目。cfg'到FUPLA目錄,從主目錄中選擇“編輯器”菜單,然后“返回”以加載新的FUPLA代碼。
Measurement function (UIfPQ)
A. Application
Measurement of voltage, current, real and apparent power and
frequency, e.g. for display on the monitor of the control unit or for
transferring to a high level station control system for further
processing.
B. Features
single-phase measurement (1 voltage and 1 current I/P)
phase-to-ground or optionally phase-to-phase voltage measurement (providing three-phase Y connected v.t's are installed)
evaluation of the fundamental frequency components
high accuracy in the frequency range (0.9 ... 1.1) fN
frequency of voltage measured unless voltage too low, in
which case current is measured; if both are too low, the display is 0.000 Hz
at least 1 measurement per second
insensitive to DC components in voltage and current
insensitive to harmonics in voltage and current
provision for compensation of circuit and measurement
phase errors. Measured variable inputs
Measured variable inputs can be connected to the following
sources:
Measured variable constant,
integer or percent range.
Protection function measured variable,
the range for angles is ±180.00° and currents and voltages
are transferred in the corresponding units.
Input from the IBB,
integer range.
Analogue channels.
3.6.4.1.6. Measured variable outputs
Measured variable outputs can be connected to the following
sinks:
Measurements Nos. 1...64.The FUPLA code has to be loaded again each time the FUPLA
configuration is changed. After making internal FUPLA changes
and copying the new versions of the files ‘project1.bin’ and
‘project.cfg’ to the FUPLA directory, select “Editor” from the main
menu and then ‘RETURN’ to load the new FUPLA code.